TY - JOUR
T1 - Accuracy of Soft Tissue Prediction in Skeletal Type III Relationship Using a Computer-Aided Three-Dimensional Surgical Simulation Planning Program
AU - Chantaraaumporn, Jiratha
AU - Putongkam, Pongstorn
AU - Tangjit, Nathaphon
AU - Tantidhnazet, Syrina
AU - Raocharernporn, Somchart
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/5
Y1 - 2023/5
N2 - Using a computer-aided, three-dimensional surgical simulation planning program, soft-tissue planning can help achieve adequate facial esthetics and patient satisfaction after orthognathic surgery. This study aimed to assess the Simplant O&O software’s soft tissue prediction accuracy. Fourteen skeletal type III patients who underwent orthognathic surgery by the same surgeons were included in this prospective study, and they were separated into two groups: the one-jaw (n = 5) and two-jaw (n = 9) groups. The software was used to analyze the preoperative (T0) and 4-month postoperative computed tomography data (T1), as well as intraoral scans. Data from cone-beam computed tomography and stereolithography from a scanned dental cast were used to reconstruct a composite skull model. Based on the presurgical CT data, the program generated a predicted soft tissue image (TP), which was then superimposed on the T1. The distances between seven T1 and TP landmarks were measured and evaluated using a one-sample t-test. In the one-jaw group, the mean error for all linear measurements was 1.73 ± 1.14 mm, whereas the mean error of the two-jaw group was 1.03 ± 0.83 mm, and both measurements were within clinically acceptable limits. Pronasele had the best correlation (mean error of 0.63 ± 0.45 mm) while soft tissue pogonion and soft tissue point B had the worst correlations (mean error of 2.87 ± 2.22 mm and 1.31 ± 0.98 mm, respectively). Even though there were some limitations, it was possible to conclude that the ability to accurately predict soft tissue changes using Simplant O&O for skeletal type III patients makes it adequate for use in clinical practice.
AB - Using a computer-aided, three-dimensional surgical simulation planning program, soft-tissue planning can help achieve adequate facial esthetics and patient satisfaction after orthognathic surgery. This study aimed to assess the Simplant O&O software’s soft tissue prediction accuracy. Fourteen skeletal type III patients who underwent orthognathic surgery by the same surgeons were included in this prospective study, and they were separated into two groups: the one-jaw (n = 5) and two-jaw (n = 9) groups. The software was used to analyze the preoperative (T0) and 4-month postoperative computed tomography data (T1), as well as intraoral scans. Data from cone-beam computed tomography and stereolithography from a scanned dental cast were used to reconstruct a composite skull model. Based on the presurgical CT data, the program generated a predicted soft tissue image (TP), which was then superimposed on the T1. The distances between seven T1 and TP landmarks were measured and evaluated using a one-sample t-test. In the one-jaw group, the mean error for all linear measurements was 1.73 ± 1.14 mm, whereas the mean error of the two-jaw group was 1.03 ± 0.83 mm, and both measurements were within clinically acceptable limits. Pronasele had the best correlation (mean error of 0.63 ± 0.45 mm) while soft tissue pogonion and soft tissue point B had the worst correlations (mean error of 2.87 ± 2.22 mm and 1.31 ± 0.98 mm, respectively). Even though there were some limitations, it was possible to conclude that the ability to accurately predict soft tissue changes using Simplant O&O for skeletal type III patients makes it adequate for use in clinical practice.
KW - orthognathic surgery
KW - simulation program
KW - soft tissue prediction
KW - virtual treatment planning
UR - http://www.scopus.com/inward/record.url?scp=85159331982&partnerID=8YFLogxK
U2 - 10.3390/app13095623
DO - 10.3390/app13095623
M3 - Article
AN - SCOPUS:85159331982
SN - 2076-3417
VL - 13
JO - Applied Sciences (Switzerland)
JF - Applied Sciences (Switzerland)
IS - 9
M1 - 5623
ER -