T1 - Assessment of the accuracy and reliability of cephsmile v.2 in cephalograms and model measurements
AU - Watcharinporn, Orrathai
AU - Dechkunakorn, Surachai
AU - Anuwongnukroh, Niwat
AU - Sinthanayothin, Chanjira
AU - Santiwong, Peerapong
AU - Bholsithi, Wisarut
AU - Suchato, Wanna
PY - 2012
Y1 - 2012
N2 - Objective: The study compared the measurement values from lateral cephalometric analysis, postero-anterior cephalometric analysis and study models between CephSmile version 2.0 and hand-traced method. Materials and Methods: Thirty sets of digital lateral, postero-anterior cephalograms and plaster models were selected randomly, uploaded and measured with CephSmile version 2.0 Program. All dental measurements were compared with manual measurements. Manual cephalometic measurements were obtained with a cepholomatic protractor and model measurements with vernier calipers. Both groups were assessed for accuracy and reliability. Mean and SD were calculated using SPSS version 11.0. Results: All CephSmile and hand-traced radiograph coefficients of variation were less than 0.10 suggesting high interexaminer reliability. No significant differences were found comparing lateral cephalograms, postero-anterior cephalograms, and plaster models between manual measurements and CephSmile Program version 2.0. Conclusion: CephSmile Software version 2.0 is as accurate and reliable as manual measurements for cephalometric analysis in orthodontic clinical treatment and planning.
AB - Objective: The study compared the measurement values from lateral cephalometric analysis, postero-anterior cephalometric analysis and study models between CephSmile version 2.0 and hand-traced method. Materials and Methods: Thirty sets of digital lateral, postero-anterior cephalograms and plaster models were selected randomly, uploaded and measured with CephSmile version 2.0 Program. All dental measurements were compared with manual measurements. Manual cephalometic measurements were obtained with a cepholomatic protractor and model measurements with vernier calipers. Both groups were assessed for accuracy and reliability. Mean and SD were calculated using SPSS version 11.0. Results: All CephSmile and hand-traced radiograph coefficients of variation were less than 0.10 suggesting high interexaminer reliability. No significant differences were found comparing lateral cephalograms, postero-anterior cephalograms, and plaster models between manual measurements and CephSmile Program version 2.0. Conclusion: CephSmile Software version 2.0 is as accurate and reliable as manual measurements for cephalometric analysis in orthodontic clinical treatment and planning.
KW - Lateral and Posteo-anterior Cephalogram analysis
KW - Model Analysis
UR - http://www.scopus.com/inward/record.url?scp=84856831946&partnerID=8YFLogxK
U2 - 10.1007/978-3-642-27323-0_52
DO - 10.1007/978-3-642-27323-0_52
M3 - Conference contribution
AN - SCOPUS:84856831946
SN - 9783642273223
T3 - Lecture Notes in Electrical Engineering
SP - 413
EP - 422
BT - Future Wireless Networks and Information Systems
T2 - 2011 International Conference on Future Wireless Networks and Information Systems, ICFWI 2011
Y2 - 30 November 2011 through 1 December 2011
ER -