TY - JOUR
T1 - Diagnostic Performance of Dengue NS1 and Antibodies by Serum Concentration Technique
AU - Luvira, Viravarn
AU - Thawornkuno, Charin
AU - Lawpoolsri, Saranath
AU - Thippornchai, Narin
AU - Duangdee, Chatnapa
AU - Ngamprasertchai, Thundon
AU - Leaungwutiwong, Pornsawan
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/2
Y1 - 2023/2
N2 - Dengue infection has been a public health problem worldwide, especially in tropical areas. A lack of sensitive diagnostic methods in the early phase of the illness is one of the challenging problems in clinical practices. We, herein, analyzed 86 sera of acute febrile patients, from both dengue and non-dengue febrile illness, to study the diagnostic performance of dengue diagnostics. When compared with detection by Polymerase Chain Reaction (PCR), dengue NS1 detection by enzyme-linked immunosorbent assay (ELISA) had the highest sensitivity of 82.4% (with 94.3% specificity), while NS1 by rapid diagnostic test (RDT) had 76.5% sensitivity. IgM detection by ELISA and RDT showed only 27.5% and 17.9% sensitivity, respectively. The combination of NS1 and IgM in RDT yielded a sensitivity of 78.4%, with 97.1% specificity. One of the essential steps in making a diagnosis from patient samples is the preparation process. At present, a variety of techniques have been used to increase the number of analytes in clinical samples. In this study, we focused on the sample concentration method. The sera were concentrated three times with the ultrafiltration method using a 10 kDa molecular weight cut-off membrane. The results showed an increase in the sensitivity of RDT-NS1 detection at 80.4%, with 100% specificity. When combining NS1 and IgM detection, the concentration method granted RDT an 82.4% sensitivity, with 100% specificity. In conclusion, serum concentration by the ultrafiltration method is a simple and applicable technique. It could increase the diagnostic performance of point-of-care dengue diagnostics.
AB - Dengue infection has been a public health problem worldwide, especially in tropical areas. A lack of sensitive diagnostic methods in the early phase of the illness is one of the challenging problems in clinical practices. We, herein, analyzed 86 sera of acute febrile patients, from both dengue and non-dengue febrile illness, to study the diagnostic performance of dengue diagnostics. When compared with detection by Polymerase Chain Reaction (PCR), dengue NS1 detection by enzyme-linked immunosorbent assay (ELISA) had the highest sensitivity of 82.4% (with 94.3% specificity), while NS1 by rapid diagnostic test (RDT) had 76.5% sensitivity. IgM detection by ELISA and RDT showed only 27.5% and 17.9% sensitivity, respectively. The combination of NS1 and IgM in RDT yielded a sensitivity of 78.4%, with 97.1% specificity. One of the essential steps in making a diagnosis from patient samples is the preparation process. At present, a variety of techniques have been used to increase the number of analytes in clinical samples. In this study, we focused on the sample concentration method. The sera were concentrated three times with the ultrafiltration method using a 10 kDa molecular weight cut-off membrane. The results showed an increase in the sensitivity of RDT-NS1 detection at 80.4%, with 100% specificity. When combining NS1 and IgM detection, the concentration method granted RDT an 82.4% sensitivity, with 100% specificity. In conclusion, serum concentration by the ultrafiltration method is a simple and applicable technique. It could increase the diagnostic performance of point-of-care dengue diagnostics.
KW - NS1
KW - dengue
KW - diagnostics
KW - ultrafiltration
UR - http://www.scopus.com/inward/record.url?scp=85149201824&partnerID=8YFLogxK
U2 - 10.3390/tropicalmed8020117
DO - 10.3390/tropicalmed8020117
M3 - Article
AN - SCOPUS:85149201824
SN - 2414-6366
VL - 8
JO - Tropical Medicine and Infectious Disease
JF - Tropical Medicine and Infectious Disease
IS - 2
M1 - 117
ER -