TY - GEN
T1 - Portable facial stimulator design and standardization
T2 - 18th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, ECTI-CON 2021
AU - Piluek, Songyos
AU - Ngamrassameewong, Sansit
AU - Jatupornpoonsub, Tirapoot
AU - Tiawongsuwan, Lattika
AU - Puanhvuan, Dilok
AU - Prasertsakul, Thunyanoot
AU - Chanubol, Ratanapat
AU - Tirakotai, Wuttipong
AU - Wongsawat, Yodchanan
N1 - Publisher Copyright:
© 2021 IEEE.
PY - 2021/5/19
Y1 - 2021/5/19
N2 - Electrical Stimulation (ES) is a famous and effective modality to restore of nerve and muscle dysfunction for facial nerve palsy. In fact, there are several parameters that strictly require controlling the ES. Additionally, the development of portable, cost-effective, and user-friendly device should be significantly improved accessibility and recovery rate of patients to induce the self-treatment at home rather than receiving therapy at hospital or rehabilitation center. To develop the proposed ES, the basic safety standard is a principal key -which is considered before applying the ES to the patients. The purpose of this study contributes the design of an established portable ES for facial nerve palsy with the manufacturing process, performance testing in lab scale, and the standardization. In the study, IEC 60601-1-2 was considered following to determine the safety from electromagnetic disturbances. The results of testing in this protocol indicated that the prototype design of ES could function normally in critical use underlying the various electromagnetic disturbances.
AB - Electrical Stimulation (ES) is a famous and effective modality to restore of nerve and muscle dysfunction for facial nerve palsy. In fact, there are several parameters that strictly require controlling the ES. Additionally, the development of portable, cost-effective, and user-friendly device should be significantly improved accessibility and recovery rate of patients to induce the self-treatment at home rather than receiving therapy at hospital or rehabilitation center. To develop the proposed ES, the basic safety standard is a principal key -which is considered before applying the ES to the patients. The purpose of this study contributes the design of an established portable ES for facial nerve palsy with the manufacturing process, performance testing in lab scale, and the standardization. In the study, IEC 60601-1-2 was considered following to determine the safety from electromagnetic disturbances. The results of testing in this protocol indicated that the prototype design of ES could function normally in critical use underlying the various electromagnetic disturbances.
KW - Current Controlled Electrical Stimulation (ES)
KW - Facial stimulation
KW - Portable Electrical Stimulator
UR - http://www.scopus.com/inward/record.url?scp=85112852553&partnerID=8YFLogxK
U2 - 10.1109/ECTI-CON51831.2021.9454836
DO - 10.1109/ECTI-CON51831.2021.9454836
M3 - Conference contribution
AN - SCOPUS:85112852553
T3 - ECTI-CON 2021 - 2021 18th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology: Smart Electrical System and Technology, Proceedings
SP - 1121
EP - 1124
BT - ECTI-CON 2021 - 2021 18th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology
A2 - Kumsuwan, Yuttana
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 19 May 2021 through 22 May 2021
ER -